Valcom Environmental Data
Acquisition System II (VEDAS II)
Features
-
21 - Analog inputs
(single ended)
-
7 - Analog input
(differential)
-
2 - 16 bit parallel
digital inputs
-
1 - 3 or 4 digit
encoder inputs
-
1 - 8 bit wind
direction (45B or 77C)
-
6 - event inputs
-
1 - wind speed (45B
or 77C)
-
2 - 500mA switched
power strobes
-
1 - 1000mA switched
power strobe
-
4 - individual
voltage references
-
2 - SDI-12 ports
-
Telephone interface
-
Data archiving
-
Goes/Argos satellite
communications capability
-
Rugged Nema
packaging
-
-40C to +50C
-
2 - RS-232C ports
with:
Detailed Description
-
The VEDAS II is a
self-contained real-time data acquisition platform. Its modular
design makes it completely user programmable and configurable. Its
high accuracy, reliability, rugged packaging and real-time software
is ideal for military, aviation, industrial, hydrological and
meteorological applications.
-
Valcom has
added a fifth generation to its family of data collection systems
with addition of the hydro-met Data Collection System (DCS).
-
The system is designed
to be a low power, reliable, small size DCS capable of being
interfaced with a variety of common sensors. A quick review of the
list of hydro-met features highlights the fact that the system is
capable of handling the majority of user needs in a cost effective
fashion.
-
With the availability
of future sensor expansion, a DCS installed now can be moved in the
field or reconfigured at some future date. The wide range of standard
sensors which can be directly interfaced to the DCS include:
- up to two separate Memomark or
equivalent 16 bit water level encoders
- a three or four digit input port
for use with Baldwin type shaft encoders
- one 8 bit parallel digital channel
free for future applications
- six event inputs for tipping
bucket rain gauge, lightning detectors, ice-out detector,
intrusion alarm, emergency signal generator, etc.
- six event inputs for tipping
bucket rain gauge, lightning detectors, ice-out detector,
intrusion alarm, emergency signal generator, etc.
- one dedicated 8 bit channel for
use with either 45B or 77C type AES anemometers
-
The new hydro-met DCS
is also over 50% smaller in size than the last generation. At the
same time the standard on-board operation memory has been increased
to 256K of EPROM and 32K of RAM.
-
Field servicing has
been greatly simplified through the introduction of a detachable and
interchangeable terminal strip. The terminal strip is an integral
part of the DCS access cover. Once all sensors, etc have been wired
in the terminal strip, they need never be disconnected except for
replacement. If the DCS needs to be cycled for maintenance work, the
internal umbilical is disconnected from the access cover and the
replacement DCS and its umbilical can then be connected to the
access cover.
-
The hydro-met DCS
represents a highly reliable, multi-disciplinary hardware and
software system.
View
Quick Reference Data
|