Valcom Limited Guelph
Valcom Limited GuelphValcom Guelph Home PageAbout UsContact InfoFrequently Asked QuestionsSearchSite MapWhat's New
Valcom Ottawa Web Site Antennas Repair & Overhaul Data Collection Accessories Other Products Product Catalogue
bot_left_nav.gif (478 bytes)


VEDAS II: Quick Reference Data

Part Name -- Valcom Environmental Data Acquisition System II (VEDAS II)

Name: Valcom Environmental Data Acquisition System II (VEDAS II)
Category: Data Collection
Photo(s): VEDAS II
Features:

* 21 - Analog inputs (single ended)
* 7- Analog input (differential)
* 2 - 16 bit parallel digital inputs
* 1 - 3 or 4 digit encoder inputs
* 1 - 8 bit wind direction (45B or 77C)
* 6 - event inputs
* 1 - wind speed (45B or 77C)
* 2 - 500mA switched power strobes
* 1 - 1000mA switched power strobe
* 4 - individual voltage references
* 2 - SDI-12 ports
* Telephone interface
* Data archiving
* Goes/Argos satellite communications capability
* Rugged Nema packaging
* -40C to +50C
* 2 - RS-232C ports with:
         - 256K EPROM (expandable)
       32K RAM (expandable)
         -
user friendly real-time software and a
            terminal strip

Description: The VEDAS is a self-contained real-time data acquisition platform. Its modular design makes it completely user programmable and configurable. Its high accuracy, reliability, rugged packaging and real-time software is ideal for military, aviation, industrial, hydrological and meteorological applications.

Valcom has added a fifth generation to its family of data collection systems with addition of the hydro-met Data Collection System (DCS).

The system is designed to be a low power, reliable, small size DCS capable of being interfaced with a variety of common sensors. A quick review of the list of hydro-met features highlights the fact that the system is capable of handling the majority of user needs in a cost effective fashion.

With the availability of future sensor expansion, a DCS installed now can be moved in the field or reconfigured at some future date. The wide range of standard sensors which can be directly interfaced to the DCS include:

    • temperature

    • relative humidity

    • battery voltage and internal temperature

    • up to four other analog sensors inputs, such as:

  • nitrogen tank pressure for service manometers
  • ice conductivity
  • solar isolation cells
  • pH or other similar water quality sensor, etc.
    • up to two separate Memomark or equivalent 16 bit water level encoders
    • a three or four digit input port for use with Baldwin type shaft encoders
    • one 8 bit parallel digital channel free for future applications
    • six event inputs for tipping bucket rain gauge, lightning detectors, ice-out detector, intrusion alarm, emergency signal generator, etc.
    • six event inputs for tipping bucket rain gauge, lightning detectors, ice-out detector, intrusion alarm, emergency signal generator, etc.
    • one dedicated 8 bit channel for use with either 45B or 77C type AES anemometers

The new hydro-met DCS is also over 50% smaller in size than the last generation. At the same time the standard on-board operation memory has been increased to 256K of EPROM and 32K of RAM.

Field servicing has been greatly simplified through the introduction of a detachable and interchangeable terminal strip. The terminal strip is an integral part of the DCS access cover. Once all sensors, etc have been wired in the terminal strip, they need never be disconnected except for replacement. If the DCS needs to be cycled for maintenance work, the internal umbilical is disconnected from the access cover and the replacement DCS and its umbilical can then be connected to the access cover.

The hydro-met DCS represents a highly reliable, multi-disciplinary hardware and software system.

Sensors

The hydro-met DCS has been developed with the user in mind. The system is easy to program and operate, and it interfaces with virtually all normally used sensors for hydrological or meteorological applications. Standard on-board software will accommodate sensors such as: 45B or 77C anemometers, servomanometer water level sensors, relative humidity sensors, thermistors, ADR's with encoders or analog voltage output or tipping bucket precipitation sensors, lightning detector, ice-out sensor, intrusion alarm, nitrogen tank pressure sensor, snow pillows, solar radiation and dew point.

Realizing that sensor technology is ever changing, the hydro-met DCS has sufficient capacity in all standard analog, event and digital input channels to accommodate new sensors requiring any of the three standard reference voltages or 8, 12, or 16 bit parallel digital inputs.

Programming

The hydro-met DCS takes advantage of a new user friendly software package which allows a fleld technician to program and initiate operation using a one page check list. The on-board DCS software provides operational prompts which guide the operator through the programming sequence. The operator is protected from entering invalid programming. The communication port is designed to use a variety of RS-232C compatible terminals.

Valcom Consulting Group Inc. offers a full range of services wlth its DCS systems, ranging from system design through manufacturing, maintenance and field installation.

Specifications

Operating Temperature: -40°F to 122°F (-40°C to +50°C)
Input Voltage: - 9.5 to 17 VDC
- Reverse/Over/Under voltage protected
Input Current: - 1 .5 ma standby
- 40 ma active
- 60 ma during AID measurement
Packing:

- NEMA 4X molded fiberglass polyester enclosure  with 2 lockable quick-release latches and 4 mounting feet
- 30.5 cmx 25.4 cmx 15.2cm (12"xlO"x6")
- Internally coated for EMI/RFI shielding

Weight: 3 kg (6.61 Lbs.) (without any options)
Peal Time Clock: ± 60 sec/month (higher accuracy with GOES)
Display / Keypad: - 20 (5x7 dot matrix) characters x 2 lines
- Display Area: 7.08 cm x 1 .15 cm
- VFD (-40°C to +85°C) or optional LCD
- Keypad: 8 keys
Communication Interface: - Two RS-232C ports
- Selectable baud rates from 300 to 57.6K
- Program terminal cable included (9 pin female D-connector for program terminal)
PCMCIA FLASH Memory Card Slot: - Accepts one, linear, type I or II, 5 V, 8 MByte PCMCIA FLASH Memory Card
-
Optional PCMCIA FLASH Memory Cards standard or rated for -40°C to +85°C
-
PCMCIA FLASH Memory Card is used to: retrieve stored data, upgrade operating system software or download user program parameters
Memory: - 1 MByte FLASH for operating system, user program and data storage (64,000 entries)
- 128 KByte SRAM
SDI-12: - Two dedicated SDI-12 ports which can support up to 10 sensors each
-
Each port can also be configured as a digital I/O or low frequency pulse counting channel
Digital I/O: - 8 I/O channels + 5 input only channels
- Output level @ 1 ma:
        4.5 V ≤ high ≤_5.0 V, low ≤_0.2 V
- Input level: 3.5 V ≤ high ≤_5.0 V. low ≤ 1.0 V
- Outout resistance: 465_Ω
- Input resistance: 200 K_Ω
Excitation Outputs: - 4 Individually programmable outputs:
     0 to 5.0 V @ 20 ma, 1.22 mV resolution, high impedance off state, load compensated
- 2 Protected individually switched 12 V outputs @ 1 amp
- 4 Protected 12 V outputs @ 1 amp
- One 5 V switched output @ 100 ma
Pulse Counter Inputs: - 16 bit resolution
- 7 Low frequency inputs: 5V pulses_≤ 100 Hz
- 2 High frequency inputs:
     20 mVrms to 20 Vrms ≤ 200 KHz
Analog Inputs: - 7 Single ended only channels
- 7 Differential or up to 14 single ended channels
- Low level AC frequency measurements
- Battery voltage (internal)
- System temperature: 0.5°C accuracy
- Input level: -5.0 V to +5.0 V
- Selectable gains: x1, x10, x100, x1000
- Resolution: 0.2 mV (gain
x1)
- Sample rate: 10 Hz to 1.8 KHz
- Input resistance: 10 G_Ω
Acquisition Interval: 1 to 86400 seconds with 1 second resolution
Options: - Internal 14.4 kbps modem (-40°C to +85°C)
- GOES satellite transmitter
- Rain shield for terminal strip
- Integrated shaft encoder
- RS-485 port instead of one SDI-12 port
- PC support software
- Internal Backup Battery (-20°C to +50°C)
 

Home | About us | Contact Us | Frequently Asked Questions | Search | Site Map | What's New

Send mail to enquiries@valcom-guelph.com with questions or comments about any of the products or services found on this web site. Valcom Logo 

©2006 All information and materials contained within are the property of Valcom Manufacturing Group Inc..